Plastic Scintillator For Radiation Monitor Supplier

about-img
  • Scintillation Detectors & Spectrometers & Radiometers | BSI.LV

    Plastic scintillation detectors covered with 8 mm back and side lead shield. HPGe semiconductor detectors with 5 cm back and side lead shield. Detectors dimensions, mm. 1050 x 200 x 50. Ø80 x 40. Number of gamma detectors per …

  • Plastic Radiation Detectors | Products & Suppliers | Engineering360

     · The FIBERTRAC 31 is a radiation -based sensor with flexible plastic sensing element for continuous measurement of liquids and bulk solids. It is suitable for level measurement under extreme process temperatures, in case of critical product features or aggressive products. The. Device Classification: Sensor-Only.

  • Design and development of a plastic scintillator based whole body β/γ contamination monitoring …

     · Plastic scintillation detectors based whole body β/γ contamination monitors are developed for use in radiation facilities. This microcontroller-based multi-detector system uses 13 plastic scintillator detectors, with minimized dead detection zones, monitoring the whole body, and conforming to the contamination limit prescribed by the regulatory authority. This system …

  • Modern detectors for radiation monitors | SpringerLink

     · The possibilities of using modern photon and neutron detectors for developing radiation monitors, specifically, LaBr3, Bi4Ge3O12, CdWO4, LiI, ZnO, Lu2SiO5(Ce), CdTe, and HgI2, microtubes from organic scintillators, nanomaterials, and detectors based on gaseous and solid-state electronic multipliers are examined. A comparison is made of conventional …

  • Southern Scientific Radiation Detection Equipment – Southern …

    Southern Scientific are specialist supplier of radiation detection equipment for the Nuclear, Medical, Security, Defence, Industrial & Research sectors. Southern Scientific Radhound

  • PRIMAS Portal Monitoring System

    Radiation detection is carried out by gamma-sensitive detectors. Every detector consists of a plastic scintillator with a volume of 13 liters and a connected, highly sensitive photomultiplier with downstream evaluation electronics.

  • Scintillation Detectors & Spectrometers & Radiometers | BSI.LV

    Plastic scintillation detectors covered with 8 mm back and side lead shield. HPGe semiconductor detectors with 5 cm back and side lead shield. Detectors dimensions, mm. 1050 x 200 x 50. Ø80 x 40. Number of gamma detectors per pillar. 4. 4. Neutron detectors.

  • CLYC Gamma-Neutron Scintillator for SPRDs and RIIDs | RMD, …

    CLYC Gamma-Neutron Scintillator. CLYC (Cs2LiYCl6:Ce) is a dual-mode gamma-neutron scintillator and the first practical detector for use as a replacement for both medium resolution gamma-ray detectors and Helium-3 proportional counter tubes for neutron detection. The ease of using Pulse Shape Discrimination (PSD) for neutron detection, combined ...

  • Scintillation Detectors | JCS Nuclear Solutions

    Specilaising in scintillation detectors since 1975. JCS have built up an industry leading portfolio of scintillation detectors and detector knowledge. Our comprehensive range of scintillation detectors covers applications ranging …

  • CsI(Tl)

    CsI (Tl) has a high effective atomic number and consequently larger cross-section of the gamma-radiation photoabsorption. For practical application, it is very important that CsI (Tl) is not hygroscopic. With relatively good radiation hardness (103 rad) …

  • Plastic Scintillators | Oncology Medical Physics

    Signal-to-Noise Ratio The biggest hurdle in use of plastic scintillators for precision dosimetry is the inherently low SNR of such detectors. There are three main sources of noise for scintillators: Cherenkov Radiation: Cherenkov radiation arising in the inactive regions of the detector may account for as much as 3% of the signal for X-ray beams and 12% of the signal for electron …

  • Scintillation, CZT Detectors & Options

    Lanthanum Bromide Scintillation…. Model LaBr 3 (Ce) Scintillation Detector is a medium-resolution scintillation detector featuring a 1.5 x 1.5 in. LED Temperature-Stabilized Scintillation…. Model NAIS-2x2 Sodium Iodide Scintillation Detector is a high-efficiency scintillation detector featuring a 2 x 2 in.

  • GRAETZ Strahlungsmeßtechnik

    high sensitive NaI-scintillation probe 2002 for the detection of β-/γ-radiation contamination probe ABG170 with large detector surface (plastic scintillator) for the detection of α-, β- and γ-contaminations basic unit automatically identifies the connected probe and

  • Plastic Gamma Sensors: An Application in Detection of …

     · INFN and ANN designed and developed a Radiation Portal Monitor (RPM) to detect gamma and neutron radiations using plastic scintillator coupled to Gadolinium. The system is a portal for the screening of vehicle and cargo containers aiming at detecting the presence of radioactive elements and, in particular, Special Nuclear Materials (SNM).

  • Radiation Monitoring Systems – Healvita Group

    This system is mobile radiation monitoring system designed for fixed installation into vehicles and mobile laboratories. The system consists of two high sensitive plastic scintillator detectors, NaI(Tl) gamma spectroscopy detector, high dose rate GM module and optionally a solid scintillation neutron detector and weather sensor.

  • Tianjin WIN-TRUST Technology Co.,Ltd

    Tianjin WIN-TRUST Technology Co.,Ltd - China supplier of Radiation Detector, Portal radiation monitor, Gamma X-ray detector, Plastic Scintillator, NaI Scintillator Company Name Tianjin WIN-TRUST Technology Co.,Ltd Location JuYing Road,Jinnan District, TianJin

  • SGC Organics Brochure

    General Description – The scintillation emission of a typical plastic scintillator has a maximum around 425 nm. Plastic scintillators are characterized by a relatively large light output — typically 25-30% of NaI(Tl) — and a short decay time of around 2 ns. This makes

  • Product Catalogue

    PLASTIC NuDET NAI Plastic scintillator detectors Premium plastic scintillation detectors and assemblies designed for wide variety of applications. Thin layers/foils are suitable for detection of protons, electrons and beta particles. Larger volume detectors are

  • Radiation Portal Monitors – Nuclear System

    Application. Radiation Portal Monitors (RPM) are permanently installed radiation detection systems designed for automated screening of pedestrians, vehicles and trains passing through the detection zone of RPM for presence of gamma and neutron radiation. The RPM alerts the security office and front line officer about the presence of radioactive ...

  • Scintillation Detectors Suppliers

    voltage supplies, scintillation detectors & R2D nuclear radiation sensors. View Supplier Save Select Apantec LLC Lansdale, PA Custom Manufacturer* $5 - 9.9 Mil 2005 10-49 Manufacturer Of Radiation Monitoring Systems For Nuclear Power Plants Call ...

  • Scintillation Detectors | JCS Nuclear Solutions

    Specilaising in scintillation detectors since 1975. JCS have built up an industry leading portfolio of scintillation detectors and detector knowledge. Our comprehensive range of scintillation detectors covers applications ranging from industrial to medical & research.

  • Nuclear Radiation Monitor

    The RAD IQ AP300 is a radiation portal designed for monitoring pedestrians and their carrying goods. The unit can be installable on doorways, hallways, walls or stand-alone. It is rapidly deployable and operational up to 48 hours without line power when it is used

  • Radiation Portal Monitor for small containers, luggage and parcels (RCCL) | SciWise Solutions Inc.

    Radiation Portal Monitor for small containers, luggage and parcels RCCL is a Radiation Portal Monitor specifically developed for the detection of potential radioactive sources or contaminated residuals in hospital and health care activity waste. RCCL operates automatically in both static and/or dynamic mode, so the operator does not have to stop in front of the detector. The …

  • Organic Scintillation Materials

    2 General Description – The scintillation emission of a typical plastic scintillator has a maximum around 425 nm. Plastic scintillators are characterized by a relatively large light output — typically 25-30% of nai(Tl) — and a short decay time of around 2 ns. This

  • Chapter 4 Scintillation Detectors

    Chapter 4 Scintillation Detectors 4.1. Basic principle of the scintillator Scintillator Ionizing radiation Light (visible, UV) Light sensor Fig. 4.1. Principle of the scintillation detectors. Scintillates are one of the oldest types of radiation detector becausemade with

  • Plastic scintillator-based radiation detector for mobile radiation …

     · Plastic scintillator-based radiation detector for mobile radiation detection system against nuclear/radiological terrorism Author links open overlay panel Sung-Woo Kwak a Ho-Sik Yoo a Sung Soon Jang a Jung Soo Kim a Wan-Ki Yoon a In Sub Jun c Kwang Hyun Kim b

  • Luggage Portal Radiation Monitoring System, Radiation Check …

    Large area plastic scintillator BF 3 scintillator or 3 He p roportional c ounters Energy range 20keV ~ 3.0 MeV Thermal neutron ~ 14MeV Sensitivity A n increase in 0. 04 μSv / h against the background level of 0.2μSv / h, alarm s in less than 1 second. D ~ ≤

  • LESSON 3: X AND GAMMA RADIATION MONITORING

    Scintillator as Survey Meters NaI(Tl) based scintillators are used both for as area monitors and portable as survey instruments. Sleek plastic scintillator based instruments with a wide range of 0.01μSv/hto 10 Sv/h are also available. Palm or credit card sized